About Master Exhaust House

We move air out of the places where work gets done.

Industrial ventilation and evaporative cooling equipment for Bangladesh — exhaust fans, air coolers, dehumidifiers and air curtains, sized to the building rather than picked off a catalogue page.

Dhaka, Bangladesh Unit 2 Ventilation & industrial cooling +880 1706-259292

Who We Are

A ventilation supplier that asks about your floor before it quotes.

Master Exhaust House supplies industrial ventilation and evaporative cooling equipment for factories, warehouses, workshops and other demanding working environments in Bangladesh.

Our approach starts with the space and the application. Floor area, ceiling height, operating conditions and required airflow are considered before equipment is selected.

The objective is simple: provide practical ventilation and cooling solutions that match the actual requirements of the building rather than selecting equipment only from a catalogue.

Company Information

Location Zirabo, Ashulia, Dhaka, Bangladesh
Unit Unit 2
Focus Ventilation & Industrial Cooling
Coverage Bangladesh
Contact +880 1706-259292
ENGINEERED AROUND THE SPACE — NOT SIMPLY SELECTED FROM A CATALOGUE.

Why Master Exhaust House

Practical engineering before equipment selection.

Good ventilation starts with understanding the space, the process and the airflow requirement — not simply choosing a fan from a catalogue.

01

Engineering First

We consider floor area, ceiling height, airflow, heat load and operating conditions before recommending ventilation or cooling equipment.

02

Application Focused

Every space has different requirements. We match the equipment to the application, working environment and required airflow rather than relying only on model names.

03

Supply & Support

From equipment supply and installation to service and spare parts, we support the system beyond the initial quotation and handover.

What We Supply

The range, by what it can actually move.

Equipment is grouped by capacity and application, because the first question in any enquiry is how much air has to shift and how large a space it has to serve.

01
↗

Industrial Exhaust Fan

High airflow

Production floors, warehouses and workshops.

02
↗

Cone Exhaust Fan

High airflow

Poultry sheds, greenhouses and large open spans.

03
≋

Evaporative Air Cooler

18,000 – 30,000 m³/hr

Open and semi-open workspaces and assembly halls.

04
◌

Industrial Dehumidifier

60 – 480 L/day

Storage rooms and humidity-sensitive production.

05
↓

Air Curtain

Width / speed

Entrances, loading bays and cold-room doors.

06
↗

Ventilation Fan

High airflow

Kitchens, welding bays and enclosed utility rooms.

How A System Gets Sized

Three numbers decide the fan. Everything else is selection.

Air changes per hour is only useful when it is connected to the actual room volume. We start with the space, calculate the required airflow and then select equipment around that requirement.

01

Room Volume

Floor area × ceiling height

02

Air Changes / Hour

The required number of air replacements per hour for the application.

03

Required Airflow

Room volume × air changes per hour.

REQUIRED AIRFLOW ROOM VOLUME × AIR CHANGES / HOUR

Worked Example — Garments Floor

Floor area
900 m²
Ceiling height
3.5 m
Volume
3,150 m³
Air changes per hour
30
Required airflow
94,500 m³/hr

Covered by three exhaust fans of roughly 32,000 m³/hr each, positioned against the relevant floor layout and the practical airflow path.

SIZE THE SPACE CALCULATE THE AIRFLOW SELECT THE EQUIPMENT

How We Work

From enquiry to handover, in four stages.

We keep the process straightforward — understand the space, determine the requirement, supply the right equipment and continue supporting the system after installation.

01

Site Details

Understand the space.

Floor area, ceiling height, existing openings, working conditions and available power are reviewed before the system is sized.

→
02

Sizing & Quotation

Calculate what the space needs.

We determine the required airflow and recommend suitable equipment based on the application and practical layout.

→
03

Supply & Installation

Put the system into operation.

Equipment is supplied and installed according to the agreed layout, with preparation for the relevant electrical and mechanical connections.

→
04

Service & Spares

Support the system after handover.

Replacement parts, service and routine support remain available after the initial installation.

✓

Industries We Serve

Ventilation built around the working environment.

Different industries create different heat, humidity and airflow conditions. Our equipment range is used across industrial, commercial and specialized working environments in Bangladesh.

01

Garments & Textile

Ventilation and cooling solutions for production floors and textile working environments.

↗
02

Poultry & Livestock

Air movement and ventilation equipment for large agricultural and livestock spaces.

↗
03

Food Processing

Ventilation and environmental control equipment for food processing and related facilities.

↗
04

Manufacturing & Logistics

Air movement solutions for factories, warehouses and logistics environments.

↗
05

Pharmaceuticals

Ventilation, cooling and humidity-control equipment for pharmaceutical working environments.

↗
06

Plastic & Packaging

Air movement and cooling solutions for production and packaging facilities.

↗
07

Workshops & Garages

Practical ventilation solutions for enclosed workshops and service areas.

↗
08

Commercial Kitchens

Exhaust and ventilation equipment for demanding commercial kitchen environments.

↗
09

Showrooms & Retail

Air movement and comfort solutions for customer-facing commercial spaces.

↗
10

Cold Storage

Air curtain, dehumidification and ventilation solutions for temperature-sensitive environments.

↗

Start With The Space

Let’s size the right system for your space.

Tell us about your building, floor area and working environment. We can help determine the required airflow and identify suitable ventilation or cooling equipment for the application.

01 SPACE

Floor area & ceiling height

02 AIRFLOW

Required air changes per hour

03 EQUIPMENT

Suitable system for the application

MASTER EXHAUST HOUSE, UNIT-2 INDUSTRIAL VENTILATION & COOLING ZIRABO, ASHULIA,DHAKA, BANGLADESH